1 day ago screwfix.com Show details

Logo recipes May 9, 2017  · What is your new cooker rated at in watts or kw (kilowatts), these things at a very minimum are required before we can give any more help tbh. KIAB Super Member. May 9, …

276 Show detail

6 days ago electrical4u.net Show details

Logo recipes Jul 28, 2023  · Table of motor kW to cable size chart is prepared based on the direct online start and star-delta starting. 3.7kW for 7.5Amps 5.5kW for 9.56 Amps for that 4Sqmm copper Cable

186 Show detail

6 days ago stackexchange.com Show details

Logo recipes Dec 3, 2019  · Cooker (range/oven/cooktop) loads are special...unless the manual says to do something different ... require a separate 40-amp circuit. Models rated at 7.2 kW and below at …

› Reviews: 7

60 Show detail

1 week ago ccalculators.co.uk Show details

Logo recipes Mar 9, 2024  · What size cable for a 10KW cooker? For a 10kW cooker, a cable size of at least 10mm² would be recommended to handle the higher power load safely. Can you run a 8.5 kW …

87 Show detail

1 week ago wikihow.com Show details

Logo recipes Feb 13, 2024  · Note that new cookers come with the required power cable. If you need a new one, make sure it is the right size. Try using a 2.5 mm (0.098 in) heat-resistant cable, for …

› Views: 173.9K

236 Show detail

5 days ago checkatrade.com Show details

Logo recipes The size of cable recommended for an electric cooker will vary depending on the size of the cooker and the length of the wire, so there’s no one size fits all solution. If the wrong cable is …

420 Show detail

2 days ago ccalculators.co.uk Show details

Logo recipes Apr 28, 2024  · Choosing the correct electric cooker cable size is essential for kitchen safety and compliance in the ... This rating is typically measured in kilowatts (kW). To ensure that the …

134 Show detail

1 day ago delonghi-cookers.co.uk Show details

Logo recipes The cable between the cooker and the cooker outlet box will need to be one of the following sizes: 13 to 16amp (2.90Kw to 3.68Kw) Cable Size 1.5mm². 16 to 20amp (3.68Kw to 4.68Kw) Cable …

90 Show detail

6 days ago diynot.com Show details

Logo recipes Mar 10, 2008  · The cooker currently in use is a Zanussi ZHF865X and is rated at 5.5kw which i calculate as ~23amps (5500/240). The currnt circuit breaker attached to this ring is a B30 …

376 Show detail

4 days ago fantastichandyman.co.uk Show details

Logo recipes Mar 20, 2018  · Connect the cable to the back of your cooker. Locate the terminal outlet box on the back of your appliance and unscrew the plate. Connect the live (brown), neutral (blue), and …

267 Show detail

1 week ago mybuilder.com Show details

Logo recipes Dec 26, 2021  · Correct electrical cable for cooker. Anonymous user 26 December 2021 - 2.34 PM. Hi I have a cooker switch which has a bs6004 6mm +2.5 cable in it (written on cable) that …

458 Show detail

1 week ago diynot.com Show details

Logo recipes Jan 17, 2013  · The way you calculate it is: the first 10a + 30% of the remainder + 5a for a socket outlet in cooker control unit (CCU) So, working back from a 15kW cooker 15000 / 230 = …

468 Show detail

5 days ago mybuilder.com Show details

Logo recipes Oct 4, 2015  · So if you install a 10Kw cooker on a 32A MCB, it will happily sit not tripping up to 46A WHICH IS FAR IN EXCESS OF THE CABLE CARRYING CAPACITY. And if run within …

222 Show detail

1 week ago electriciansforums.net Show details

Logo recipes Dec 17, 2017  · Our 17.7 kw Rangemaster is on 10mm but the OEM said 6mm would be good enough1 . Reply to Octopus. Upvote 0 Downvote. 123-Arms. Joined Dec 26, 2012 Messages …

142 Show detail

1 week ago electriciansforums.net Show details

Logo recipes May 26, 2009  · I need to wire 7,5 kW cooker, the cable run will be 15 meters clipped direct what would be the MCB and cable size. from my calculation I work out it should be 40A B MCB and …

466 Show detail