Cooker ratings and kWh / kW, options for 32Amp circuit
1 week ago diynot.com Show details
Bedfordshire. Country. 12 Oct 2012. #1. We are replacing a standalone cooker with an unknown rating, the short cable to the wall is 6mm. The circuit is fused at 32A which would suggest a …
› Share
› Oven and Hob Current Rating
Why is a cooker circuit generally 6mm and 32a
1 week ago electriciansforums.net Show details
Dec 18, 2015 · I think the use of 6mm for 32A cooker circuits is historical. In the days of BS3036 re-wireable fuses, only 6mm met the extra current carrying requirements associated with those …
› Estimated Reading Time: 5 mins
Running a new cooker circuit | Screwfix Community Forum
3 days ago screwfix.com Show details
Aug 24, 2013 · A standard 32A cooker circuit wired in 6mm2 would be adequate for both of these appliances. Use one circuit for each. Terminated in to a 45A double pole cooker switch …
32A cooker circuit — MoneySavingExpert Forum
1 day ago moneysavingexpert.com Show details
10 December 2016 at 1:51AM. A standard 30/32A circuit is adequate for domestic cooking appliances up to 15kW. Just choose a cooker that suits. There is a chance that the original …
Cooker rating and wiring - MyBuilder
3 days ago mybuilder.com Show details
Oct 4, 2015 · MCB's do not trip on over current for a long time and though every device has a fusing factor, a common factor for MCB's is 1.45 x In, so in this case 46A. Now the regulations …
Cooker Installation - 32amp fuse circuit breaker, able to go up to a …
2 weeks ago mybuilder.com Show details
Nov 8, 2014 · Hi it depends on the power of your cooker, length of cable and method of installation. if your cooker is 7000w (7KW) and you install 15meter of 6mm twin and earth …
Electric range cooker on 32A circuit - UK Whitegoods Domestic …
1 day ago ukwhitegoods.co.uk Show details
Aug 8, 2017 · Electric range cooker on 32A circuit. 08-08-17, 07:36 PM. We have a cooker circuit that is 6mm T/E, on a 32A MCB. Because of the layout it would be prohibitively costly …
Junctioning 32A cooker circuit with a 13A spur. - Page 1 - EEVblog
1 week ago eevblog.com Show details
Feb 9, 2022 · Yes, the feeding circuit is 32A on 6mm cable. You mention that the point at which the cable splits does not need protecting as long as the cables it splits into being capable of …
4 mm Cooker circuit 32amp MCB | on ElectriciansForums
1 week ago electriciansforums.net Show details
Mar 11, 2015 · Diversity applied (no socket at cooker switch) 10A + 30% remainder 10+9.51 = 19.51. with diversity applied Ib <In<It. can't find any reference in the regs to a 4mm cooker …