Spur Off Cooker Switch Problems Recipes

1 week ago screwfix.com Show details

Logo recipes Screwfix Select. Jun 23, 2021. #3. Its an interesting one, because of course you can get a cooker switch and socket combination. The main reason this isn't done is because the cable to the cooker switch is say 6mm with a 32A MCB, if you then spur a socket it 2.5 the MCB is too …

› Electricians' Talk Light switch help michaelrn84; Thursday at 3: 59 PM; Replies 2 Views 59. Thursday …
› Spur of Cooker IS Hi folks Is it acceptable to spur of the cooker isolation switch to a FCU then …

483 Show detail

2 days ago diynot.com Show details

Logo recipes Apr 2, 2005  · Fishingsmurf said: My cooker runs off it's own 32A circuit, connected to a cooker switch unit, and then wired into a CCU. CCU could be “Cooker Control Unit” or “Cooker …

122 Show detail

6 days ago diynot.com Show details

Logo recipes Nov 9, 2006  · Country. 9 Dec 2009. #2. If you spur off teh cooker circuit you will need to do it in the same size cable as the existing. As that will be 6mm or 10mm then you wont be able to …

345 Show detail

1 day ago electricianforum.co.uk Show details

Logo recipes Apr 27, 2012  · The spur cable comes out the back of the cooker, through the adjoining kitchen cupboard and through the wall to the lounge! The cooker radial is supplied from a 30A …

183 Show detail

1 week ago screwfix.com Show details

Logo recipes Screwfix Select. May 15, 2021. #2. Change the 32amp mcb for a 16amp mcb and wire the new cooker into the existing outlet plate using 2.5mm flex. If you go for the 13 amp cooker you …

264 Show detail

1 week ago ultimatehandyman.co.uk Show details

Logo recipes Mar 21, 2007  · A cooker switch with socket is allowed because the maximum assumed demand from the socket outlet is 13A , and by the regulations, there is diversity to be applied to …

266 Show detail

4 days ago screwfix.com Show details

Logo recipes Dec 28, 2015  · The spur to a twin socket could be part of a kitchen ring circuit with the cooker being on it. If the cooker circuit is separate with its attached "kettle" socket it should be left …

443 Show detail

2 days ago electriciansforums.net Show details

Logo recipes 24. May 20, 2012. #1. I have a Cooker circuit on 4mm T&E using a 32A MCB. I have established that my dining room 3 double socket outlets is wired as a radial spur directly off the cooker …

322 Show detail

1 week ago electriciansforums.net Show details

Logo recipes Absolute. May 9, 2011. #2. I also believe the cooker should be a dedicated circuit. I think what you say would work, but i wouldn't do it as i don't think it's the "done thing". A socket off the outlet …

328 Show detail

2 weeks ago screwfix.com Show details

Logo recipes Jun 3, 2017  · Hi folks Is it acceptable to spur of the cooker isolation switch to a FCU then 2.5mm from the load side to a twin socket? ... that a 2.5mm on a 32 MCB is essentially a radial off the …

Side 90 Show detail

4 days ago diynot.com Show details

Logo recipes Aug 29, 2006  · 1) cooker circuits are best used only for cookers, however, 2) there is a provision in the relevant regs for an additional 'point', e.g. the 3pin socket often found on cooker isolation …

350 Show detail

1 week ago mybuilder.com Show details

Logo recipes From the cooker outlet plate or the outgoing leg of the cooker circuit you could split this into 2x 13amp power supplies However as the previous answer advised its best to get this done by a …

269 Show detail

1 week ago screwfix.com Show details

Logo recipes Jan 13, 2007. #8. Well, what I mean is, that if the cooker is on 6mm, and a spur is the usual 2.5, then the reduction in cable size would need to be fused not only to meet disconnection time, …

90 Show detail

2 weeks ago stackexchange.com Show details

Logo recipes I have a fused spur switch in my kitchen with a dishwasher attached. Recently the dishwasher stopped turning on, so I removed it from the bay and noticed two things. The neon light is quite …

325 Show detail

1 week ago screwfix.com Show details

Logo recipes Jun 23, 2021  · Yes,either use a cooker switch with a 13A socket for the oven or spur off the switch with 2.5mm to a socket.As others have said the 2.5 cannot be overloaded since the fuse in the …

198 Show detail

1 week ago screwfix.com Show details

Logo recipes Nov 13, 2023  · appliance electrics spur spur off a spur T. tashao New Member . Nov 13, 2023 #1 ... of the room and the electrical points. 4 DS (double sockets), 2 FCU (washing machine and …

175 Show detail